{"id":524,"date":"2018-11-28T11:48:57","date_gmt":"2018-11-28T10:48:57","guid":{"rendered":"https:\/\/focusewelding.wpcomstaging.com\/?page_id=524"},"modified":"2023-02-09T15:04:49","modified_gmt":"2023-02-09T15:04:49","slug":"medical","status":"publish","type":"page","link":"https:\/\/www.focus-welding.com\/de\/medical\/","title":{"rendered":"Medical Devices"},"content":{"rendered":"<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-joining-structuring-engraving-and-polishing-reliable-perfection-for-medical\">Joining, structuring, engraving and polishing: reliable perfection for medical!<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-reliable-and-clean-joining\"><strong>Reliable and Clean Joining<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The high requirements in the medical sector for cleanliness, reliability and high precision are addressed with the MEBW-60. Due to the contactless processing under high vacuum, contamination can be avoided or reduced to a minimum. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The technologies unique ability is shown perfectly when it comes to joining materials like stainless steel, titanium, gold and the complex task of welding shape memory alloys (Nitinol) .  The microscopic quality of joints can be observed at any time with the scanning electron microscope mode (SEM) available on the micro electron beam welding machine MEBW-60 with a resolution up to about 25 \u00b5m. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The very fine beam with as less as 30 microns allows for delicate welds as shown in the example below.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-micro-structuring\">Micro Structuring<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To increase the acceptance of implants it is state of the art to use a surface modification like glas bead blasting. The big advantage of an electron beam structured surface is the possibility to generate structures with defined dimensions. With the ability of a high frequency beam deflection hundreds of these microstructures can be generated in a few seconds. One possibility is SurfiSculpt\u00ae&nbsp;which is shown in the pictures below.&nbsp;<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Surfi-Sculpt was invented by Bruce Dance at TWI in 2002, and has been the subject of on-going research and development. TWI has obtained granted patents for this technology in Europe, USA, Japan and a number of other countries (EP1387734, EP1551590, US6670571, US7667158 &amp; others).<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2011.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"600\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2011.jpg\" alt=\"\" class=\"wp-image-687\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2011.jpg 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2011-300x234.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2021.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"600\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2021.jpg\" alt=\"\" class=\"wp-image-688\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2021.jpg 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/micro20surface20modification20for20medical20implants2021-300x234.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Micro welding of thin wires made of Nitinol<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">One of the interesting biocompatible materials for medical implants is the Nitinol, a shape memory and superelastic alloy, which consists of 50 at.-% nickel and 50 at.-% titanium. Micro Electron Beam welding allows to join Nitinol wires for example to increase the radial force of stents. The wire diameter ranges from 200\u00b5m down to 30\u00b5m.&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"674\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2-1024x674.png\" alt=\"\" class=\"wp-image-2196 size-full\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2-1024x674.png 1024w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2-300x197.png 300w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2-768x505.png 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2-500x329.png 500w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2020\/12\/stents1_2.png 1038w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Welding of the wire crossings (left) of a one wire hand winded Nitinol stent.Electron optical pictures of a stent (upper) and (right) winded in a fixture prepared for welding.<\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"706\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2021\/01\/stents2_RWTHpsd.png\" alt=\"\" class=\"wp-image-2251 size-full\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2021\/01\/stents2_RWTHpsd.png 925w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2021\/01\/stents2_RWTHpsd-300x229.png 300w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2021\/01\/stents2_RWTHpsd-768x586.png 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2021\/01\/stents2_RWTHpsd-500x382.png 500w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Picture from welds (upper) of wire crossings<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cross section (lower) of spot welded stent of Nitinol wires<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Beside the fine focused electron beam, power control in the sub watt regime is of essence:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Left: 140\u00b5A (8,3 Watt) beam current: molten wire<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Top: 130\u00b5A (7,8 Watt) beam current: perfect joint<\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-engraving-and-polishing\">Engraving and polishing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Especially in the medical sector it is necessary to monitor medical components through their entire life cycle. With the implemented engraving technology it is possible to mark your parts directly after your welding process.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If a surface roughness of just a few microns or smoothening of edges is needed, the electron beam can be used for polishing. This technique is available for every metal surface and can be done in a few seconds.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-3-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20engraving1.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"600\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20engraving1.jpg\" alt=\"\" class=\"wp-image-691\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20engraving1.jpg 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20engraving1-300x234.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing1.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"600\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing1.jpg\" alt=\"\" class=\"wp-image-693\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing1.jpg 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing1-300x234.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing2021.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"600\" src=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing2021.jpg\" alt=\"\" class=\"wp-image-692\" srcset=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing2021.jpg 768w, https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/02\/electron20beam20polishing2021-300x234.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Joining, structuring, engraving and polishing: reliable perfection for medical! Reliable and Clean Joining The high requirements in the medical sector for cleanliness, reliability and high precision are addressed with the MEBW-60. Due to the contactless processing under high vacuum, contamination can be avoided or reduced to a minimum. The technologies unique ability is shown perfectly [&hellip;]<\/p>","protected":false},"author":7,"featured_media":550,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-524","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.2.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Medical Devices | FOCUS Welding<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.focus-welding.com\/de\/medical\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Medical Devices | FOCUS Welding\" \/>\n<meta property=\"og:description\" content=\"Joining, structuring, engraving and polishing: reliable perfection for medical! Reliable and Clean Joining The high requirements in the medical sector for cleanliness, reliability and high precision are addressed with the MEBW-60. Due to the contactless processing under high vacuum, contamination can be avoided or reduced to a minimum. The technologies unique ability is shown perfectly [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.focus-welding.com\/de\/medical\/\" \/>\n<meta property=\"og:site_name\" content=\"FOCUS Welding\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-09T15:04:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2018\/11\/fotolia_55841409_xl_cmyk05x.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1712\" \/>\n\t<meta property=\"og:image:height\" content=\"1140\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"cmerkel\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"2\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.focus-welding.com\/#organization\",\"name\":\"Focus GmbH\",\"url\":\"https:\/\/www.focus-welding.com\/\",\"sameAs\":[\"https:\/\/www.youtube.com\/user\/FOCUSGmbH\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.focus-welding.com\/#logo\",\"inLanguage\":\"de\",\"url\":\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2019\/03\/2014_FOCUS_NoGmbH_NoSlogan_web.png\",\"width\":414,\"height\":200,\"caption\":\"Focus GmbH\"},\"image\":{\"@id\":\"https:\/\/www.focus-welding.com\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.focus-welding.com\/#website\",\"url\":\"https:\/\/www.focus-welding.com\/\",\"name\":\"FOCUS Welding\",\"description\":\"Electron Beam Welding and Laser-in-Vacuum Welding Machines\",\"publisher\":{\"@id\":\"https:\/\/www.focus-welding.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.focus-welding.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.focus-welding.com\/medical\/#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/www.focus-welding.com\/wp-content\/uploads\/2018\/11\/fotolia_55841409_xl_cmyk05x.png\",\"width\":1712,\"height\":1140,\"caption\":\"\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.focus-welding.com\/medical\/#webpage\",\"url\":\"https:\/\/www.focus-welding.com\/medical\/\",\"name\":\"Medical Devices | FOCUS Welding\",\"isPartOf\":{\"@id\":\"https:\/\/www.focus-welding.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.focus-welding.com\/medical\/#primaryimage\"},\"datePublished\":\"2018-11-28T10:48:57+00:00\",\"dateModified\":\"2023-02-09T15:04:49+00:00\",\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.focus-welding.com\/medical\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/pages\/524","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/comments?post=524"}],"version-history":[{"count":11,"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/pages\/524\/revisions"}],"predecessor-version":[{"id":3139,"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/pages\/524\/revisions\/3139"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/media\/550"}],"wp:attachment":[{"href":"https:\/\/www.focus-welding.com\/de\/wp-json\/wp\/v2\/media?parent=524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}